2J-X series plunger metering pump is plunger /piston metering pump with duplex heads. Two liquid heads work separately with independent gear ratio mechanism. It is an ideal proportioning metering dosing pump for two different chemicals. The check valve is double-ball design for increased accuracy.
Capacity range 5-300lph,8-400bar
• Duplex heads with individual adjusting system;
• Flow rate of each head can be adjusted via unique adjusting mechanism from 0-100% independently;
• The adjustment can be carried when pump is in operation or at stop;
• The steady accuracy is ±1% from 30%-100% of the maximum output;
• Automatic operation is achieved by variable speed drive;
• Special application for high temperature or low temperature is available with cooling jacket or heating jacket;
Plunger reciprocates in the pump chamber, under the action of the check valves, the liquid is sucked and discharged alternately. When undertaking suction action,the plunger is pulled back, which makes the pressure immediately drops inside the liquid end. The discharge valve is closed due to the low pressure in the chamber, and the suction valve ball is open with the liquid being sucked into the pump head chamber. When the suction stroke ends, the plunger movement momentarily stops and the pressure in the liquid chamber equalizes with the pressure in the suction line causing the suction valve ball to reseat. When the plunger pushes forward, the pressure immediately rises inside the liquid chamber. When the liquid chamber pressure rises above the discharging line pressure, the discharge valve ball is pushed upward and the liquid is discharged into the discharge line. The discharge valve is closed when suction. The suction valve is colsed when discharging.This can prevent from backflow. To obtain accuracy dosing, the discharge line pressure should higher than the suction line.
Model | 50Hz | 60 Hz | Pressure | Plunger Dia. (mm) |
Stroke Length (mm) |
Power kW(HP) |
Inlet&Outlet Size | Connection Size | |||||
Flow (lph) |
Flow (gph) |
SPM | Flow (gph) |
Flow (lph) |
SPM | (Bar) | (Psi) | ||||||
2J-X5/38 | 5 | 1.3 | 96 | 1.6 | 6 | 115 | 380 | 5510 | 6 | 20 | 0.37(0.5) | DN6 | DN15 (union for welding) |
2J-X8/21 | 8 | 2.1 | 2.5 | 10 | 210 | 3045 | 8 | ||||||
2J-X16/13 | 16 | 4.2 | 5.1 | 19 | 130 | 1885 | 10 | ||||||
2J-X25/9 | 25 | 6.6 | 7.9 | 30 | 90 | 1305 | 12 | ||||||
2J-X40/5.4 | 40 | 11 | 13 | 48 | 54 | 783 | 16 | ||||||
2J-X60/3.5 | 60 | 16 | 19 | 72 | 35 | 508 | 20 | ||||||
2J-X100/2.2 | 100 | 26 | 32 | 120 | 22 | 319 | 25 | DN10 | |||||
2J-X130/1.7 | 130 | 34 | 41 | 156 | 17 | 247 | 28 | ||||||
2J-X160/1.3 | 160 | 42 | 51 | 192 | 13 | 189 | 32 | ||||||
2J-X200/1.0 | 200 | 53 | 63 | 240 | 10 | 145 | 35 | ||||||
2J-X250/0.8 | 250 | 66 | 79 | 300 | 8 | 116 | 38 | ||||||
2J-X300/0.6 | 300 | 79 | 95 | 360 | 8 | 116 | 42 |